Sunlight & content
Share screen orientation, show times and sample content. Evaluate contrast and readability at the intended daylight conditions and viewing positions.
Plan for the daylight.
Build for the event.
Modular LED display cabinets for outdoor stages, festivals and live productions. Match image detail, site conditions and the complete equipment scope before you order.
Confirm the cabinet format and model drawing in your configuration.An outdoor display specification needs to connect the image with the installation and operating conditions.
Share screen orientation, show times and sample content. Evaluate contrast and readability at the intended daylight conditions and viewing positions.
Set the wall dimensions, nearest viewer distance and content type. Compare the native resolution before preparing graphics or choosing a processor.
Confirm front and rear protection, connectors, temperature limits and the planned response to changing site conditions for the selected model.
Choose hanging or ground stack. Define the structural review, cable routing, power distribution and access requirements for that layout.
The table and planner use the published 500 × 500 mm cabinet references. Other formats require their own model dimensions and specifications.
| Parámetro | P2.604 | P2.976 | P3.906 | P4.807 | P6.25 |
|---|---|---|---|---|---|
| Distancia entre píxeles (mm) | 2.604 | 2.976 | 3.906 | 4.807 | 6.25 |
| Resolución del Gabinete (px) | 192 × 192 | 168 × 168 | 128 × 128 | 104 × 104 | 80 × 80 |
| Resolución del módulo (px) | 96 × 96 | 84 × 84 | 64 × 64 | 52 × 52 | 40 × 40 |
| Densidad de píxeles (píxeles/m²) | 147,456 | 112,896 | 65,536 | 43,264 | 25,600 |
| Brillo (cd/m²) | 4,000–5,000 | 4,000–5,000 | 4,000–5,000 | 4,000–5,000 | 4,000–5,000 |
| Frecuencia de actualización (Hz) | 1,920–3,840* | 1,920–3,840* | 1,920–3,840* | 1,920–3,840* | 1,920–3,840* |
| Power, avg / max (W/m²) | 260 / 800 | 260 / 800 | 260 / 800 | 260 / 800 | 260 / 800 |
| Front / rear protection | Request the selected model’s front / rear ratings and connector specification. | ||||
Reference values from Highcolor’s outdoor series specifications. *Refresh rate varies by selected product configuration. Confirm the exact cabinet, LED package, front/rear protection, connectors and operating limits in the final quotation. A cabinet protection rating does not establish a complete system’s weather or structural limits.

Review live video, sponsor graphics and event information in the expected ambient light. Plan the transition to evening brightness as part of the show workflow.
Use the site brief to define the supporting equipment and documentation. Keep the operating plan tied to the selected model and installation.
Include your site requirements ↗Request separate front/rear ratings, connector and cable specifications, and the correct installation condition for each seal. Include processor and power-distribution protection in the equipment scope.
Provide wall height, exposed area, hanging or ground-stack method and ground conditions. Request a project-specific structural design and operating limits. Cabinet weight alone does not establish support capacity.
Use maximum display power as a reference input for the electrical design. Specify cable lengths, circuit layout, earthing, protection and the mains or generator supply with the responsible project team.
Confirm weather monitoring, brightness adjustment, service access, spare modules and the site team’s operating procedures. Include camera tests when the wall will appear on a live feed.
Explore a flat wall of 500 × 500 mm cabinets. Use the resulting canvas and load references to start the system quotation.
Packing reference: eight 500 × 500 mm cabinets per case. Case estimates exclude spares and accessories; confirm the actual packing list.
Display-only estimates use native cabinet pixels, 7 kg per cabinet and 260 / 800 W/m² average / maximum power. Average power is a reference, not measured event consumption. This planner does not calculate structural capacity, ballast, current, generator size or weather limits.
Ask for panel specifications and the supporting system in the same quotation. Confirm what is included, optional or supplied by your production team.
Cabinet format, pitch, quantity, LED and driver configuration, brightness, refresh setting, calibration data and front/rear environmental ratings.
Processor inputs and capacity, receiving system, signal mapping, power/data connections, cable lengths, redundancy requirements and protected equipment locations.
Compatible hanging or ground-support equipment, connection hardware, approved configuration drawings, rated limits, service tools and maintenance clearances.
Flight cases, gross packing dimensions and weight, spare modules, power supplies, receiving cards, setup records, warranty and delivery terms.
Stage backdrops, side screens and live performance content.
Live viewing, sponsor visuals and audience information.
Temporary outdoor displays for product and campaign events.
Temporary displays for organized outdoor audiences.
It is the published brightness range for these outdoor references. Suitability depends on sun direction, exposure, screen surface, content and viewing positions. Share your site and show schedule, and evaluate the proposed configuration under comparable daylight conditions.
Request both ratings for the exact cabinet model, along with connector specifications and the conditions required to maintain protection. Keep processors, distribution equipment and other exposed components within the agreed system protection plan.
No. Enclosure ingress protection and structural performance are different specifications. The project requires a support design and operating limits for its wall area, height, rigging or ground support, site conditions and installation hardware.
Use the complete load schedule with the responsible electrical designer. Include the display’s maximum power, controllers, ancillary equipment, distribution losses and relevant startup and supply requirements. The planner provides display power references; it does not recommend a generator rating.
With the published 500 mm cabinet references, a 6 × 3 m wall gives 1536 × 768 pixels at P3.906 and 1248 × 624 at P4.807. Choose using viewing distance, content detail and budget. The pitch change alone does not establish a different protection rating or structural capacity.
Provide location, show times, site exposure, screen orientation, dimensions, support method, ground conditions, available power and the required operating plan. Confirm model temperature limits, protected connections, weather monitoring and the project team’s stop or shutdown procedures.
Request a model recommendation, cabinet layout and itemized equipment proposal for your outdoor rental fleet or event project.
sales@highcolorled.com ↗